The Equator’s motion platform is a floating platform supported by three straight driving rods, with the driving point and feedback point sharing the same origin. There is also a counterweight balancing mechanism inside the body to share vertical loads. There are two types of mistakes that are most likely to be made when writing this: one is to mystify the “counterweight” as some kind of universal shock absorber, and the other is to talk about the structural details that have not been officially announced as common knowledge. This article only focuses on one thing – separating the four items that can be checked on site from the three things that cannot be moved: abnormal noise, drift, load difference, and power-off maintenance can be checked; The parts that cannot be moved are the interior of the counterweight, pre tensioning, struts, and hinge points. The abnormal balance mainly affects stability and abnormal noise, and does not directly change geometric accuracy. This conclusion determines the direction of the entire article’s handling.

1. Original text: What are counterweights, floating platforms, and struts

Item 7 in the official component diagram does indeed exist

First, nail down the fact that is most easily mistaken by the two extremes. The official installation and controller guide for Renishaw (document ID 132816300 and 500 are applicable) provides numbered component diagrams, with item 7 named Counterbalance mechanism, which stands for counterweight balancing mechanism. That is to say, this institution is not a folk legend, nor is it a modified part of a certain machine. It is an official entry on the official component diagram.

Also related to this article on the same image are: 3 Floating/moving platform, 4 Support strut, 5 Top casting, 6 Drive strut, 8 Upper pivot/Hooke’s joint, 9 Support arm, 12 Parallel constraint mechanism, and 13 Fixture plate.

This list itself is a true or false question material: It has no lead screw, no synchronous belt, and no Z-axis column inside.Many engineers who have switched from traditional CMM systems see that the platform will float, so they tend to look for Z-axis balance cylinders or screw counterweights, which deviates from the direction from the beginning.

1.2 This machine does not have a screw or belt drive, and the drive is a three pole linear drive

The structure of Equator is a parallel kinematic mechanism. The three struts are respectively P, Q, and R axes, each of which is an independent linear driving unit. The two ends are connected to the base and platform through Hooke hinges, and the struts themselves only bear tensile and compressive forces and do not bear bending moments.

This is directly related to the counterweight. In traditional serial structures, the “counterweight” is almost always tied to the screw: the counterweight block moves up and down along the guide rail, or the cylinder directly pushes the Z-axis slider. And here the drive is the linear extension and contraction of the strut, and the responsibility of the counterweight is not to compensate for the weight of a vertical screw, but to keep the floating platform in a reasonable force and smooth motion in the vertical direction.

There is another layer that is often overlooked but crucial: the grating is mounted on the strut, and the driving point and feedback point are of the same origin. **The controller commands how long the strut has traveled, and the grating reports how long the strut has traveled. The two are the same point on the same physical strut. The consequence is that the control system is unaware of any deviations that occur outside of the grating reading and before the real spatial point (such as hinge point gaps, slight deformations under strut loads, differences in platform posture and solution assumptions). The distinction between “stability problems” and “geometric problems” in Chapter 4 relies on this one point.

1.3 Internal structure of counterweight: not officially disclosed

The official component diagram provides the name and location of item 7, but does not disclose the internal structure – what elastic components are used, whether there is pre tightening, whether there is adjustable interface, and how much adjustment is made, all of which are not disclosed. There are no user oriented adjustment steps found in the random manual.

Therefore, any content related to internal components, stiffness, stroke, preload, and adjustment methods shall not be expanded or speculated. Do not write ‘usually two springs pulled together’, do not write ‘changing preload by adjusting nut’, and do not write ‘what bar should the chamber pressure be’. This type of content may seem professional, but it is actually a grafting of other structures or general experiences; Readers follow the search, but if they can’t find it, it’s still a small matter. If they find it and use it as an official value to adjust, it’s a personal and equipment risk.

1.4 Support rod and Hooke hinge: observable, non removable

Support strut (item 4) and Hooke hinge (item 8) * * are a set: the support strut participates in constraining the platform’s degrees of freedom, locking the motion in the non driving direction, and establishing the solution relationship of the three struts; Hooke hinge is a two end rotating pair that allows the strut to rotate freely during expansion and contraction without introducing additional bending moments. The 12th parallel constraint mechanism and the 9th support arm belong to the same system.

The common feature of this type of component is that its status can only be indirectly judged by external sound, reciprocating consistency, and power-off maintenance, and it does not have the conditions for on-site disassembly. **Special tools and assembly standards are required for disassembly, and alignment, pre tightening, and lubrication during reassembly must be carried out in accordance with the original factory specifications; Even if it is reinstalled, it is no longer in its original state, and the kinematic model is calibrated against the original state.

1.5 “Weighting” does not equal “shock absorption”, this is the most common misconception

Many people associate the word ‘counterweight’ with tuned mass dampers in buildings and vibration dampers in cars, thinking that their function is to absorb vibrations. This association is not valid here.

The function of the counterweight balancing mechanism lies in balancing: making the vertical force on the floating platform reasonable, so that the load on the driving strut falls within the design range, and the platform will not settle or drift on its own during static and slow motion. It solves static and quasi-static force problems, not dynamic vibration problems.

There are other sources of vibration: installation foundation and foot state, impact sources such as surrounding stamping machines or air compressors, acceleration and deceleration planning, and grating signal interference. Their performance is’ the measured numbers are shaking ‘, and the performance of the counterweight problem is’ the platform cannot stop, rebounds, makes abnormal noises, and the three poles have uneven loads’.

One sentence distinction: The counterweight tube “can hold”, while the shock absorber tube “does not shake”.If two things are mixed together, a typical misjudgment will occur – if the platform shakes slightly on site, it will be determined that the counterweight is malfunctioning; The real reason may be loose feet or external vibration sources.

1.6 Physical intuition of a floating platform: in what state it “floats”

Think of the platform as a casting supported by three extendable rods, and constrained in degrees of freedom by struts and hinge points. When the controller is enabled and the three poles each establish a position closed loop, the platform is actively pushed to the commanded position and held there, at which point it is “holding force”.

After power failure or emergency stop, the active holding force disappears.At this time, the platform is only subjected to the combined forces of gravity, counterweight balance, hinge point and strut constraints, and friction. This directly determines two safety matters:

Firstly, in the event of a power outage, the platform may no longer be in the same position as before. **The settlement amount depends on the direction of the counterweight design allowance, and the direction of the allowance is not officially disclosed, so it cannot be assumed that it will stop in place after a power outage. 300 units weighing 25 kg, the phenomenon may be minor; 500 units weigh 74 kg, which is much more noticeable.

Secondly, any manual intervention in a power-off state may cause the platform to start moving in a position that you did not anticipate. **This is also the starting point of the next chapter’s safety tips.

2. Criterion layer: Four on-site inspections that can be conducted

Each item is given action and criterion, followed by a direction when it fails; All four items do not require any internal structure or specialized instruments to be altered. Three preconditions run through the entire chapter. Prerequisite 1: Status Record – Record the time, room temperature, duration of power on (preheating), and last re mastering time before each inspection. If not recorded, the reading can only be qualitative. Front two: Change only one variable at a time – change the stylus, move the fixture, change the program, and adjust the room temperature at different times.Front three: Safety status * * – Do not touch the platform, support pole, or reach into the work area when powered on.

2.1 First item: reciprocating abnormal noise

Action.Under the condition of no parts, execute a reciprocating program covering the main stroke with the controller – repeat the three axes in one direction, and add a simple three-axis linkage. Do not lean forward when standing on the outside of the machine. The second person can listen at a distance of about one meter: one person can listen closely to high frequencies, while the other can listen to low frequencies from a distance, making it easier to distinguish the source of the location compared to one person repeatedly listening.

Criterion.Qualified: The entire journey has a smooth noise level, there is no additional “lo” sound during the switching moment, and there is no whistling sound that changes with speed at the speed change point. There are three typical forms of abnormalities. One is the single abnormal noise at the moment of reversing, and the tone does not change significantly with speed – leaning towards the hinge point or supporting strut constraint surface, and reversing is the moment when the gap is released. The second is continuous low-frequency buzzing or friction sound, varying with position – biased towards the inside of the strut driving unit or interference with the wiring, which needs to be cross verified with the driving unit inspection. The third type is the dull sound strongly correlated with the vertical position, which only occurs when the platform is located at the upper or lower part of the travel – this type is only related to the force state in the direction of the counterweight. But this is only a correlation prompt, not a diagnostic conclusion: The sound only indicates that ‘there is an abnormal force state in this area’, and it cannot be determined whether the counterweight is on site.

Recording method.Recording on mobile phone with axis position information, recording axis type, direction, position range, and speed; Slow motion video recording of directional changes.

2.2 Second item: Platform static drift

Action.Move the platform to a fixed command position in the middle of the working volume, keep it enabled and stationary. Firstly, visually check the alignment of the platform and fixture plate edge relative to the fixed reference (such as the fixed machining surface on the base casting); When a finer dial gauge is needed, the head should be placed on the upper casting and the needle should point to the same reference on the platform. Let it stand for more than ten minutes and read it every minute.

Criterion.Qualified: The reading enters a stable range after one or two minutes, and then remains basically unchanged within the minimum division of the table, or only makes small, slow changes in the same direction as room temperature (thermal drift, see 6.1). Exception: Continuous unidirectional movement – walking in one direction for several minutes without stopping or returning, this is a sign of ‘something slowly losing balance’.

Pay attention to two points. Firstly, the reading of a dial gauge does not equal the positional accuracy. It is only the displacement of the gauge needle relative to the gauge seat, and can only be determined by whether it moves or how much it moves. Secondly, observation should be conducted during a period without external vibration interference; When stamping or driving past, the reading keeps shaking and cannot be judged. Wait for the interference to disappear and redo.

2.3 Third item: Three axis load difference

Action.Let me first explain a reality: The data sheet and user guide do not disclose the load or current reading interfaces for each axis, nor do they have user readable load value definitions.So the feasible approach is indirect comparison, not reading:

One is to jog the controller, allowing the P, Q, and R rods to move in and out along their respective axes at the same speed setting, compared to sound, start stop smoothness, and whether there is any difficulty in a certain section of the stroke. The second is to check whether the appearance of the three struts is consistent when the platform is in the middle position – whether there are visible bends in the body, and whether the posture angles of the hinge points at both ends are similar. The third is to slowly link and walk in a circle, to see if there is a slight sinking on one side of the platform posture.

Criterion.Qualified is three-axis consistency: similar sound, start stop, smooth travel, and symmetrical appearance posture. The abnormality is that one axis is significantly different from the other two axes: the sound is louder, the middle section is stuck, the corresponding platform side sinks when stationary, and there is a flat fixed direction on the linkage circle.

The boundary is very clear: The conclusion of ‘excessive load on a certain axis’ cannot be given on site.The only thing that can be given is’ the performance of one axis is different from the other two axes’, and it needs to be combined with the fourth result to roughly determine whether the force distribution is on the strut side or the counterweight side. Any statement about the difference in load, without official readings to support it, should not be included in the report.

2.4 Fourth item: Maintain position after power failure

Action.The highest safety requirement should be followed in order: the platform should be placed in a safe position slightly below the middle of the working volume, the clamping area should be cleared, and there should be no suspended workpieces or measuring needles interfering; Normal shutdown, wait for the controller to completely stop outputting; Observe for visible settling or jumping during the first thirty seconds after power failure; Do not turn off the power and manually push the platform (see 2.5). Instead, use “power on to check position” – power on to enable reading of the current position and compare it with the commanded position before power off.

Criterion.Qualified: There is no visible jumping or obvious sinking after power outage, and the position of power on is basically the same as before power outage. There are two types of anomalies: one is obvious sinking or jumping at the moment of power outage – the vertical balance changes significantly after losing the main force, and the force is most directly directed towards the counterweight side; The second issue is that the platform did indeed move during the power-off period, but it was not visible visually when it was stationary after the power was cut off but when it was powered back on, there was a noticeable position correction.

Please note that the results are affected by room temperature, initial running time, and platform location, so they must be repeated under the same conditions (recommended three times) to determine the degree of dispersion rather than a single result. A single anomaly is not sufficient for qualitative analysis, only three instances in the same direction are meaningful.

2.5 Regarding the ‘Manual Push Platform’: Write only according to official statements

The official installation and controller guide provides a handling instruction of: moving or lifting the entire machine at 300 requires two people, using the handheld position reserved on the base casting ; 500 can only be lifted mechanically. These are all guidelines for moving the entire machine.The official document does not provide operational guidelines for “users manually pushing the sports platform” – it is not “officially prohibited”, but “the manual does not provide such guidance”.

Both forms of excessive writing are incorrect: cannot write ‘official strictly prohibits platform promotion’ – this sentence cannot be found in the manual, it is a rule for the official; It is also not allowed to write ‘can be pushed’ – without work instructions, it is impossible to push out safety boundaries, withstand thrust, and meet post push review requirements.

So this article does not provide steps on how to push, nor does it write ‘someone has done this before’ as a reference method. To determine the motion status of the platform, there are two paths that do not involve manual pushing and pulling: one is to coordinate the controller’s jog with three-axis comparison, and the other is to observe the power outage in item 2.4. Both read only data and do not apply external force; To determine the conclusion, submit it to a professional repair party or the original factory channel. Push pull platform is not available for any model when powered on or enabled.

2.6 Summary of Four Inspection Criteria and Three Disciplines

First provide a summary table, then give three rules of discipline.

Inspection items Action points Qualification criteria Abnormal form Abnormal direction
Reciprocating noise No component reciprocating motion, one person close and one person listening from a distance, covering the spindle stroke and a section of linkage Smooth noise throughout the entire stroke, no additional noise during reversing, no whistling that changes with speed Single reversing abnormal noise; Continuous friction sound that varies with position; Dull sound strongly correlated with vertical position hinge point or constraint surface; Drive unit or wiring; Vertical force state (only associated with prompts)
Platform static drift Neutral enable to stand still, dial gauge is placed on the same reference as the upper casting and platform, read once per minute After one or two minutes, it enters the stable range, only slowly changing in the same direction as the room temperature continues to move unidirectionally for several minutes without stopping slowly loses balance, needs to be read in conjunction with the power-off holding result
Three axis load difference Comparison of moving three axes at the same speed; Observe the appearance and posture of the strut; Slow linkage circle inspection posture Consistent three-axis sound, start stop, and smooth travel, symmetrical appearance posture Excessive single axis sound, stuck middle section, corresponding side sinking, and fixed direction flattening on the circle Differences on the strut side, cannot be classified as’ load exceeding limit ‘
Maintain position after power outage Neutral stop power outage, clear the area, observe for thirty seconds, re power on the position, repeat three times No visible settling or jumping, re power on position is basically the same as before power outage Sinking or jumping at the moment of power outage; There is a noticeable position correction when powering on again The vertical balance state has changed, pointing towards the counterweight side

Firstly, there is no numerical threshold.Official documents do not have noise decibel values, drift rate limits, or power outage settlement limits; Forcing a number (such as’ drift less than 1 μ m per minute is normal ‘) is a fabrication. All four criteria are trend criteria and consistency criteria. Secondly, the criterion only focuses on whether there is an anomaly, regardless of what the anomaly is, at a granularity of ‘which group it points to’.Thirdly, reliability depends on the number of repetitions: each item must be repeated at least three times, and only when all three times are consistent will it be recorded; If two rounds are inconsistent, add more rounds or switch time periods to redo, without taking the average.

3. Disposal layer: Check how to arrange, record how to write, and three things that cannot be moved

3.1 Inspection Sequence and Safety Tips

Arrange in order of “from outside to inside, static to dynamic, powered on to off”:

The first step is static visual inspection and status recording.Stop the machine and cut off the power. From the outside, inspect the platform, three struts, upper casting, fixture plate, and base casting for visible deformation, oil leakage, scratches on the struts, abnormal accumulation near the hinge points, and pressure on the wiring. No tools are needed, but it can block a considerable number of obvious problems.

Step two, reciprocating abnormal noise.Electricity must be applied, the work area must be cleared, and no one should lean forward. Step three, three-axis load difference.Both are powered on items and share one heating process with the second step. Step four, static drift.Allow to stand still, time-consuming, and allow for simultaneous observation of environmental changes. Step five, maintain the position after power failure.Put it last because it needs to be shut down and powered off.

Five safety tips, it is recommended to copy them into the team operation manual:

  1. Do not push or pull the platform, or touch the struts and hinge points when powered on or enabled. **At this point, the platform has active holding force, which opposes external forces and closed-loop control.
  2. For any activity that requires manual access to the workspace, first confirm that the stop button has been pressed and the machine has stopped outputting.The part number of the stop button varies depending on the model (300 is A-5504-025500 is A-6078-0259), and its location can be found in the accompanying manual.
  3. Do not place your hands in the gap between the platform and the upper casting, or under the platform when the power is off. **After a power outage, the platform may not be in its original position or may move due to external forces.
  4. Move or lift the entire machine according to the model: 300 people can use the handheld position on the base casting, and 500 can only be lifted mechanically.Single person moving is the most common source of accidents.
  5. If any abnormalities are found, stop using and record them. Do not cover up the phenomenon with adjustments. **Adjusting to ‘no sound’ without clarifying the internal status is the worst outcome.

3.2 The first thing that cannot be moved: remove the counterweight

Cannot be dismantled.There are three layers of reasons, and each layer can be rejected if it is established separately.

The first layer is information: The internal structure is not officially disclosed, and there is no assembly drawing, pre tightening value, or assembly sequence that can be compared after disassembly. To put it back with the naked eye, what is restored is a “rotatable mechanism”, not the “factory state mechanism”.

The second layer is calibration: the kinematic model and the assumptions on which the uncertainty depends are established for a known state. Disassembling and assembling the counterweight will change the vertical force state of the platform. Even if the structure is completely restored, the behavior of the platform under power failure and low load will be different from before disassembly, and these differences will not be displayed on the screen.

The third layer is responsibility: the official categorizes the internal components of the host as parts that cannot be repaired by users themselves, and component replacement is handled as a whole replacement. This constraint applies to user self repair, not to professional repair providers – but it cannot be used to prove that ‘users can also dismantle’; The difference lies in the fact that professional maintenance providers have tools, assembly benchmarks, post repair verification capabilities, and assume quality responsibility.

3.3 The second thing that cannot be moved: adjusting the pre tension

Cannot be adjusted.The covered objects include Hooke hinge pre tightening, constraint states at both ends of the strut, and anything that looks like an adjustment nut or adjustment washer.

The reason is that pre tightening is a bi-directional compression window: if it is insufficient, the gap will be exposed during reversing, manifested as reverse difference and abnormal noise; Excessive rotation leads to an increase in resistance, manifested as low-speed crawling, uneven return, and even minor positional errors during motion. The reasonable value depends on the structural dimensions and materials, and the official unpublished window value.

The most common thing on site is to hear abnormal noise, identify it as “loose”, and find a place that looks like it can be twisted twice. The abnormal noise often becomes smaller or even disappears because the gap is compressed – but the machine has changed from “having a gap” to “over pre tightening”, which subsequently manifests as low-speed unsmooth and decreased repeatability, directly affecting measurement stability, and this new state has no baseline.

3.4 The third thing that cannot be moved: remove the strut and hinge point

Cannot be dismantled.The strut and Hooke hinge are part of the kinematic relationship. Disassembly and assembly introduce three types of changes: assembly alignment, contact state of constraint surfaces at both ends, and inevitable small deformations during disassembly and assembly. None of them will sound an alarm, but they will change the mapping between the command position and the actual spatial point.

The 12th parallel constraint mechanism and the 9th support arm belong to this category: they are located inside the structure, require reference for disassembly and assembly, and require geometric verification for reinstallation. The correct approach is to use indirect methods from 2.1 to 2.4 to describe the state clearly – which axis, which direction, what speed, what phenomenon – and then ask a professional maintenance provider with the description.Being able to describe a phenomenon clearly is more valuable than being able to disassemble and see it clearly: description is the basis for judgment, disassembly is disposal, and disposal should be done by the party capable of bearing the consequences.

3.5 Clear boundary of self maintenance scope on site

Put ‘can’ and ‘cannot’ on a table:

Action Can it be executed on its own Basis and explanation
Cleaning kit (A-5504-9055, including spare dust filter) Available Official maintenance item; Disable cleaning agents
Controller fan filter replacement (A-5696-0120, 12 piece set) Available Official maintenance item; High pollution environment to be replaced within 6 months
Needle inspection and replacement (based on official needle sample selection) Can be Routine maintenance; After replacement, check if the probe is bent (SP25 criterion ≤ 4 μ m)
External visual inspection, abnormal sound auscultation, static drift observation Okay This article only observes the immovable structure through four inspections
Internal inspection or disassembly of counterweight balance mechanism Not allowed Internal structure not officially disclosed
Pre tightening adjustment of hinge points, disassembly and assembly of struts cannot affect kinematic relationships, no publicly available adjustment values
Disassembly or maintenance of the drive strut body Not allowed The strut contains a grating, which is a measuring component
Replacement of internal components of the host Not allowed There are no user repairable components inside the host

The lines that cannot be moved in the table cannot be broken through by being “careful”: being careful only reduces the probability of incidental damage and cannot fill the gaps in assembly standards and post repair verification.

3.6 Disposal branch: result combination interpretation

Combination of inspection results Interpretation direction Suggested disposal
Four normal, occasional and non reproducible single abnormal noises Suspected transient interference (external impact, wire contact) Record time and working conditions, observe closely, and do not move the structure
There is only slight settlement after power outage, and the position is basically the same when power is restored. There is a slight change in the vertical balance state, and no other abnormalities are observed. The trend has been confirmed three times; If it occurs continuously and the amplitude increases, report it to a professional maintenance provider
Abnormal noise+power outage settlement in the same direction Vertical stress state and constraint surface state change simultaneously Stop using the abnormal workstation, report to the professional maintenance party for evaluation, and do not make on-site adjustments
Inconsistent three-axis+Flat fixed direction on the linkage circle Abnormal support or constraint state on one side Record the axis and direction, and report to the professional maintenance party; No precision acceptance will be conducted during this period
Static drift continues unidirectionally, but in the same direction as room temperature More likely to be thermal drift, not counterweight Processed according to the thermal compensation and preheating process, not classified as mechanical anomaly
Abnormal noise+accuracy retest exceeding tolerance (confirmed by external instruments) Separate judgment required: may or may not be from the same source First locate according to the geometric detection process, do not attribute the weight to the abnormal noise

The last line contains the core conclusion, which will be elaborated in the next chapter.

4. Boundary layer: how to distinguish between abnormal weight distribution and accuracy deviation

4.1 Conclusion: Weighting mainly affects stability and abnormal noise, and does not directly change geometry

This conclusion needs to be logically explained, otherwise it is easy to be taken as a deduction. The counterweight works on the vertical force balance, determining how the platform behaves when it loses active holding force or is under low load. The geometric accuracy is determined by another set of quantities: the correspondence between the effective length of the three struts and the instructions, the contact state of the hinge points at both ends, the consistency between the platform posture and the calculation assumptions, and the position of the probe components relative to the platform. The intersection of the two sets of quantities is very small.

Why not directly change the geometry: Geometric accuracy comes from the mapping of “how long the strut goes, where the platform goes”, and the counterweight does not participate in the mapping calculation, only changes the vertical load during mapping execution. Load changes can cause small elastic deformations, but these error sources are not on the same order of magnitude as hinge clearances and strut deformations. More importantly, the closed-loop position of the three struts in the enabled state will pull the platform back to the commanded position.

Why does it mainly affect stability and abnormal noise: When the closed-loop is released (power failure, emergency stop) or during low load slow motion, the role of weight distribution becomes prominent; The platform position is no longer actively corrected, and the imbalance is directly manifested as drift, settlement, and abnormal noise caused by changes in contact state.

**The correct causal relationship is that abnormal noise and drift are direct manifestations of the counterweight side problem; Additional evidence (such as laser interferometers, ballbar instruments, standard ball repeatability, and benchmark verification) is required to establish accuracy deviation. Judging the accuracy as bad when there is abnormal noise, and calculating the balance when there is a deviation, are both misplaced attributions.

4.2 Under what circumstances cannot one move on their own

Article 1: It involves everything inside the structure.Under no circumstances should the disassembly and assembly of the counterweight interior, hinge point pre tensioning, struts, and constraint mechanisms be within the scope of self disposal (reasons see 3.2 to 3.4). Article 2: Four inspections show persistent abnormalities – more than three rounds in the same direction, or a monotonically increasing amplitude; Single or occasional observation first. Article 3: Abnormal noise has affected the measurement results, for example, if the same standard part is repeatedly measured during the abnormal noise period and the reading becomes more discrete, it is not a mechanical single point problem.Article 4: If the abnormal power outage is accompanied by position correction after re powering on, it indicates that the platform has indeed moved and the amplitude exceeds the normal range. **Article 5: Abnormal noises related to counterweight after collision, liquid ingress, overload and other events may result in completely different stress states after the event, and the original baseline is no longer applicable.

4.3 Under what circumstances should we use the original factory channel or RBE

For situations involving structural deformation reconstruction (including visible deformation of base castings and upper castings), damage to the linear encoder scale body, and the need to use the original factory encryption upgrade package or permit migration, it is recommended to return to the factory or have a Renishaw business representative (RBE) handle them. Third party professional maintenance providers have the ability to perform board level/component level repairs and non original factory calibration assembly repairs (replacing hinge points, performing calibration after reassembly), but they cannot replace the original factory’s re calibration, which requires original calibration devices and version calibration conditions.

To avoid excessive wording: Do not write ‘only factory handles counterweight related issues’.To be precise, the internal inspection and disassembly of the counterweight belong to the scope of professional maintenance and original factory channels; Observation and recording of the status can be done on site.

4.4 An easily overlooked boundary: Do not use adjustments to eliminate phenomena

The value of the four checks lies in establishing traceable status records, not in ‘fixing whatever is discovered’. Seeing a strange noise, there happened to be a place nearby that could be twisted. Twisting it made the sound quieter – it erased a clue that could have been located and brought the machine to a new state without a baseline. The order is always record first, then evaluate, and then dispose of: the cost of recording is low, and the cost of rework for disposing of mistakes is much higher.

5. Verification layer: How to prove ‘now is good’ and record table

5.1 Checking is not the same as repairing, keep two things separate

The easily confused point is that the four checks do not change any status, so there is no such thing as “post repair acceptance”. It corresponds to baseline confirmation – confirming that the current status is normal and recording it as a reference for subsequent changes. The scenario that truly requires’ post repair acceptance ‘is after the relevant components have been disposed of by a professional repair party; At that time, the acceptance requirements were consistent with the inspection caliber in this article, because only when the caliber was consistent could comparisons be made.

5.2 Baseline Record Form (one per unit)

The table is divided into two sections: the upper section contains the condition field, which determines which data can be compared with; The lower half is the result field. If one condition field is missing, the result can only be used as a qualitative description.

Field Fill in content Fill in timing
Machine model and serial number 300/500/X-500 and serial number When established
Check date and time Accurate to minutes Each round
Room temperature and humidity On site measured values Each round
Continuous power on duration Duration from startup to inspection start (preheating state) Each round
Last re mastering time Date and time Each round
Needle configuration Needle model and length, have they been replaced? Each round
Repetitive abnormal noise Yes/No; Axis type, direction, position range, speed per round
Static drift Initial reading, stabilization time, total change within ten minutes Each round
Is the difference in three-axis performance consistent; Inconsistent axis and phenomenon description Each round
Settlement after power outage Whether there is visible settlement; Does it jump within 30 seconds? Each round
Power off – reset potential difference difference between the command position before power off and the reading after power on each round
Abnormal photos and recordings File number and storage location When there are abnormalities
Inspector and reviewer Name Each round

5.3 Three round repeated record table (for single inspection)

Use the table below for a single inspection, fill it up in three rounds, and then make a summary and interpretation. The function of the summary column is to transform a “single observed phenomenon” into a “qualitative conclusion”: the same phenomenon is considered stable only when it appears in the same direction three times; Only one round appears, which is under observation.

Round Abnormal noise location Total drift change Three axis consistency Power outage settlement Position difference Conclusion
Round 1 Consistent/Inconsistent (axis type) None/Yes TBD
Round 2 TBD
Third round The qualitative analysis can only be determined if all three rounds are consistent
Summary interpretation Number of occurrences in the same direction Trend (stable/increasing) Whether coaxial Whether in the same direction Trend Normal/observed/reported for repair

5.4 Acceptance criteria after professional maintenance and disposal

If the relevant components have been disposed of, the acceptance shall follow the five criteria, and only when all of them meet the requirements will it be considered a closed loop: ① Four inspections, retesting, and baseline before disposal are of the same caliber and have not deteriorated; ② External geometric inspection (if done) is comparable to before disposal, with no new feature distortion; ③ Head deflection ≤ 4 μ m; ④ The standard ball’s multi-directional repetitive dispersion returns to the level before disposal; ⑤ After re mastering, immediately test the standard parts and ensure that they match the certificate values, with a clamping position difference of ≤ 1 mm. Article 5 is the fundamental prerequisite for comparison machines, and any disposal involving platforms or struts must be redone, and the previous mastering results cannot be used.

5.5 Two practical requirements for recording

Requirement 1: Keep the original, not just the conclusion.Filling in ‘normal’ does not contain any information. To fill in ‘abnormal noise: none; drift: initial reading 0.003 mm, stable after about 90 seconds, total change of 0.004 mm in ten minutes’. Requirement 2: Evidence must be retained for any abnormalities.Record, video, and photo with timestamp and indicate the shooting location and machine status.

6. Supplementary layer: Common misjudgments, time period selection, and quick reference table

6.1 Misclassification 1: Treating thermal drift as a balancing problem

The performance is that the platform moves slowly when it is stationary, in the same direction as room temperature, and becomes more pronounced shortly after startup. This is hot, not a counterweight. Criterion: Changing the ambient temperature or extending the preheating time, the phenomenon changes accordingly, which is heat; No matter how the temperature is changed, it remains unchanged before considering the mechanical side. This is also the reason why it is necessary to record the preheating time and room temperature in 2.2- if not recorded, the numbers read cannot be explained.

6.2 Addendum: Selection of Inspection Period

Abnormal noise, drift, and power-off maintenance are greatly affected by the inspection period. The most easily overlooked thing is that the nearby stamping machine has just started work and is not working, so inspections are done during this period, and the data is beautiful; As soon as the stamping machine was turned on, abnormal noise and drift appeared simultaneously, but it was mistaken as machine deterioration. Suggest fixing the time period with both production load and quiet gap, and recording the status of surrounding equipment in the table. If the abnormality only occurs in a certain shift, it is mostly related to the operation mode of the shift (higher feed rate, more biased clamping, frequent emergency stops), and can only be detected by the “shift” and “operator” fields in the record.

6.3 Misclassification 2: Treating external vibrations as platform instability

The manifestation is that the reading keeps shaking when the platform is stationary, with no direction and appearing with external events (such as neighboring stamping, air compressor start stop, and driving passing by). The criterion is time domain correlation: the shaking matches the time point of the event and disappears at the end of the event. Misjudging as a counterweight will lead to a long detour, and the first step is always to ‘find a quiet period’.

6.4 Quick Check Table: Can’t Check/Can’t Move/Who Should I Ask

Phenomenon What can be done on site What cannot be done on site Who is recommended to contact
Instantaneous abnormal noise during reversing Recording positioning axis, direction, position, speed Tighten any seemingly loose parts Professional repair team evaluates hinge points and constraint surfaces
Platform settlement after power outage Three repeated observations and recording of amplitude and direction Pushing the platform under power outage status Professional maintenance team; Structural components go through the original factory channel
Inconsistent three-axis performance Comparison of jog, appearance posture, observation of linkage circle Determination of one axis load exceeding limit Professional maintenance team with phenomenon description
Static continuous unidirectional drift Observation of the dial gauge by standing still, eliminating heat and external vibration Adjusting the counterweight or changing parameters to cover up Eliminating heat and vibration still present and reporting for repair
Accuracy retest exceeds the tolerance but there is no abnormal noise Follow the geometric detection process to use external instruments Attributed to the counterweight Geometric detection process+professional maintenance party
Suspicious condition inside the counterweight Record phenomenon, stop using Disassemble and inspect Professional repair party or original factory channel

Frequently Asked Questions (FAQ)

Q1: Does the presence of a counterweight mechanism on the official component diagram indicate that it is an adjustable component that should be regularly inspected and adjusted during maintenance?

No. The component icon shows the 7th item Counterbalance mechanism, indicating that it is part of the structure, but not an adjustable component. The official has neither disclosed the internal structure nor provided any user oriented adjustment steps or values. The prerequisite for adjustability is the existence of publicly available adjustment amounts, judgment criteria, and reproducible post adjustment verification methods, none of which are available. The correct approach is to clearly record the external manifestations (abnormal noise, power outage settlement, static drift), and hand over internal matters to a professional maintenance party.

Q2: Is counterweight just shock absorption? The platform is a bit shaky, can we adjust the weight to solve the vibration?

No. The counterweight balancing mechanism solves the problem of vertical force balance, allowing the platform to have a reasonable force state when losing active holding force or low load; It doesn’t care about vibration. There are other sources of jitter: foundation and foot conditions, surrounding stamping machines or air compressors, acceleration and deceleration planning, and grating signal interference. The troubleshooting sequence is external (whether there are quiet periods or unstable feet) first, and then parameters. Counting the shaking on the counterweight is both a detour and has no executable action.

Q3: After the power outage, the platform position changed. Is the counterweight damaged?

We cannot draw such a conclusion, we need to divide it into three things. Firstly, the disappearance of active holding force after power failure is a normal phenomenon; Whether to move or not depends on the direction of the weight allowance and the current position. The direction of the allowance is not officially disclosed, so it cannot be assumed to be stationary. Secondly, look at the amplitude and trend – three repetitions in the same direction with an increase in amplitude are considered abnormal. Thirdly, check if it is caused by heat. If the three wheels are consistent, the direction is fixed, and the amplitude does not change with temperature, it is necessary to report to a professional maintenance party.

Q4: Can you manually push the platform on site and feel if there are any gaps or lags?

According to the official statement: The official installation and controller guide only provides the handling instruction of “two people are required to move/lift the whole machine, and the handheld position on the base casting (300) can be used. If it is 500, it can only be mechanically lifted”, and does not provide instructions for users to manually push the motion platform.So it cannot be written as’ officially prohibited from pushing ‘, nor can it be written as’ can be pushed’ or ‘there is no problem doing this’. Whether there are gaps or lags on the platform can be indirectly judged by observing the power outage and comparing it with the three-axis in item 2.4; Do not push in the powered on or enabled state.

Q5: I heard an abnormal noise and measured it with a laser interferometer. The accuracy is qualified. Can we ignore this abnormal noise?

We can’t completely ignore it, but don’t mix noise and accuracy together. The issues of weight distribution and constraint mainly affect stability and abnormal noise, without directly changing the geometric mapping. Therefore, it is reasonable to say that ‘there is abnormal noise but the accuracy measured by external instruments is qualified’. The correct disposal is to record the abnormal noise as a traceable description (which axis, which direction, what speed, what position interval), and then encrypted observation: continue to observe occasionally, and if there is an increasing trend, bring the record to seek professional maintenance.

Q6: If there is really a problem with the counterweight, is there any way to “deal with it” on site to continue production?

It is not recommended to make any ‘counter’ actions. The performance of the counterweight side is stability and abnormal noise. Relying on on-site adjustment to suppress the phenomenon will erase clues and bring the machine to a new state without a baseline. There is only one feasible temporary measure – reduce usage intensity and encrypt observation: avoid the location and speed ranges where abnormalities occur, shorten the continuous operation time of a single operation, encrypt the four checks to once per shift and record the amplitude; Stop using when the amplitude increases.

Q7: How to determine if the load on a certain strut is too high? Can you read the current or load value?

The data sheet and user manual do not have publicly available interfaces for load or current readings, nor do they have user readable definitions of load values, making it difficult to provide on-site information on how much the load is biased. The feasible approach is indirect comparison: comparing the sound of three axes moving at the same speed, the smoothness of start stop, and whether there is local jamming during the stroke; Check if the appearance and hinge posture of the three poles are symmetrical; Slowly link and circle to see if one side of the platform sinks slightly. The result obtained is that ‘one axis performs differently from the other two axes’, not’ load exceeds the limit ‘, and should be considered in conjunction with the power-off maintenance result.

Q8: The strut and Hooke hinge seem to be just mechanical parts. Can they be disassembled, cleaned, and oiled themselves?

No. The strut and Hooke hinge are part of the kinematic relationship, and disassembly and assembly will change the alignment of the two ends, the contact state of the constraint surface, and introduce small deformations; The three do not trigger an alarm, but will change the mapping from the command position to the actual spatial point. The official categorizes the internal components of the host as parts that cannot be repaired by users themselves. What can be done on site is to describe the phenomenon clearly – being able to describe the phenomenon clearly is more valuable than being able to disassemble and see it clearly.

Data source explanation

The technical parameters and structural description of this article are quoted from official Renishaw documents: Equator 300 Data Sheet (H-5504-8251-06-A, 2026-02), Equator 300 Specification Manual (H-5504-8252-04-A), Equator 500 Data Sheet (H-6078-8310-01), Equator Comparison Instrument User Guide (H-5504-8500), Equator Installation and Controller Guide (ID 132816/107657), Equator Controller Technical Instructions (H-5504-4000-01-A, 2011-01). The component diagram entries (including item 7 Counterbalance mechanism, item 4 Support strut, item 8 Upper pivot/Hooke’s joint, and item 12 Parallel constraint mechanism) shall follow the installation and controller guidelines; The total weight of the machine is 25 kg (300), 74 kg (500), and 140 kg (X-500) according to their respective data sheets; Test head deflection criterion ≤ 4 μ m according to the common error table in the usage guide; The clamping position difference is ≤ 1 mm according to the clamping requirements in the data sheet.

The internal structure, adjustable items, and adjustment values of the counterweight balance mechanism are not publicly disclosed in official documents, and this article does not describe or speculate on them. The official installation and controller guide does not provide instructions for users to manually push the sports platform. This article only states this fact and the relocation guide for 300, and does not represent an official ban. The criteria for the four checks in the article are trend criteria and consistency criteria, and there is no numerical threshold in the baseline, so no numerical limit is set. The description and boundaries of third-party professional maintenance capabilities (warranty impact, post repair verification requirements) are industry practices and not official specifications. The article does not mention specific customers, amounts, and brand comparisons.


Need a specific repair plan?

Every Equator fault eventually comes down to a specific machine type, duty cycle and batch. The criteria and procedures in this article can be used as a shop-floor checklist; when something does not add up, talk to us directly:

Item Detail
Company NINGBO JCE INDUSTRIAL TECHNOLOGY CO., LTD. (JCETech)
Address Room 12B17, Building 2, Zone A, Ningbo R&D Park, Juxian Subdistrict, Hi-Tech Zone, Ningbo, Zhejiang 315048, P.R. China
Contact Mr. Li / Mr. Zhang
Phone +86 157-5780-7400 (Mr. Li), +86 132-2194-1413 (Mr. Zhang)
Online booking jcetech.cn/contact

Repair intake and on-site service are handled at the same address. Please call before shipping a unit so transport and scheduling do not have to be repeated.